PTFE hydrophobic syringe filters are applicable for filtration of gaseous or organic solvent-based samples. The natural hydrophobic membrane exhibits broad chemical resistance and unsurpassed temperature stability to address aggressive sample matrixes and extreme temperature situations. Due to the membrane’s hydrophobic nature, PTFE filters can be utilized as a moisture barrier in venting applications.
Technical Data
Materials | Housing | PP | ||
Membrane | PTFE | (Polytetrafluoroethylene) | ||
Wettability | Hydrophobic | |||
Physical Properties | Pore Size | 0.22 μm, 0.45 μm | ||
Filter Diameter | 13mm | 25mm | 33mm | |
Filtration Area | 0.72cm² | 3.4cm² | 4.5cm² | |
Maximum Operating Pressure | 6bar | 3bar | 2bar | |
pH Range | 1.0 – 14.0 |
Product Information
SKU | Material | Pore Size | Diameter(mm) | Sterile | Printing | Outer Ring Color | Packaging |
C0000646 | PTFE Hydrophobic | 0.22um | 13 | NO | YES | Pink | 100pcs/pk. |
C0000647 | PTFE Hydrophobic | 0.45um | 13 | NO | YES | Red | 100pcs/pk. |
C0000648 | PTFE Hydrophobic | 0.22um | 25 | NO | YES | Pink | 100pcs/pk. |
C0000649 | PTFE Hydrophobic | 0.45um | 25 | NO | YES | Red | 100pcs/pk. |
C0000666 | PTFE Hydrophobic | 0.22um | 33 | NO | YES | Pink | 100pcs/pk. |
C0000667 | PTFE Hydrophobic | 0.45um | 33 | NO | YES | Red | 100pcs/pk. |
Features
Excellent chemical resistance for use with organic matrices.
* Naturally hydrophobic membrane provides excellent flow rates and high loading capacities.
* Exceptional temperature stability.
* Organic solvent recommended.
Chemical Incompatibilities
* Perchloric acid
* Methylene chloride (limited exposure)
* Dioxane, DMF, formic acid >50%
* Aqueous-based sample matrix (unless filter is pre-wetted with an alcohol)
Application
* HPLC and organic solvent sample preparation and clean up.
* Dissolution sample analysis.
* General sample preparation prior to analytical analysis.
* Elevated temperature samples, caustic or acidic solutions.
Select by Sample Volume
Sample Volume | Filter Diameter | Filtration Area | Hold-up Volume | Retention Volume |
< 10mL | 13mm | 0.72 cm² | < 25μl | < 25mL |
10mL to 100mL | 25mm | 3.4 cm² | < 100μl | < 100mL |
100mL to 200mL |
33mm |
4.5 cm² |
< 125μl |
< 125mL |
Select by Pore Size
Cleaning Operation | Optimal Pore Size |
Sterile Filtration | 0.20 µm |
Thorough Cleaning | 0.45 µm |
Clear Filtration | 1 - 2 µm |
Pre-Filtration | 5 µm |
Select by Diameter
Filter Diameter | Volume to be Filtered |
4 mm | < 1 ml |
13 mm | 1 - 10 ml |
25 mm | 10 - 100 ml |
30 mm | > 100 ml (fast filtration) |
Select by Pressure of Syringe Volumes
Syringe Volume | Pressure Bar / PSI |
1 ml | 10 / 150 |
3 ml | 7.0 / 100 |
5 ml | 5.0 / 75 |
10 ml | 3.5 / 50 |
20 ml | 2.0 / 30 |
How to use a syringe filter?
1. Select the Right Filter:
Membrane Type: Ensure compatibility with your sample (e.g., PTFE for organic solvents, PES for aqueous solutions).
Pore Size: Choose the appropriate pore size (commonly 0.22 µm or 0.45 µm).
2. Prepare the Syringe:
Attach the syringe filter to the syringe securely.
Ensure both are sterile if required.
3. Draw the Sample:
Fill the syringe with the sample, avoiding air bubbles.
4. Filter the Sample:
Hold the syringe with the filter attached.
Press the plunger gently to pass the sample through the filter into a clean container.
5. Post-Filtering:
Ensure the entire sample has been filtered.
Dispose of the used filter according to your lab’s guidelines.
Tips:
Apply steady pressure to avoid damaging the filter.
Pre-filter or centrifuge samples if clogging occurs.
Related Resource
1. What Is a Syringe Filter Used For? A Comprehensive Overview
2. Understanding PTFE Syringe Filters: Applications and Advantages in Laboratory Practice
3. Differences Between Aqueous and Organic Membrane Filters
4. Chemical & Material Compatibility Database
More product knowledge and the latest information are being continuously updated. Please follow our official blog to get the latest industry trends and product information at any time!
WHY CHOOSE US?
* Providing a wide range of Lab consumables.
* Variety OEM/ODM services and short delivery time.
* Rich experience with multinational companies.
* Dimensional accuracy for modern robotic autosamplers.
* Help to collect, identify, organize and protect your samples.
* Class 100,000 grade cleaning room, strict QC and R & D department center.
* With environmentally friendly packaging material.
* Cooperating with famous universities for R&D.
* Superior logistics system to offer door to door services.
* Efficient service and competitive price.
ALWSCI's mission is to provide quality guaranteed products and attentive service for Environmental Protection, Academic Research,Pharmaceutical Manufacture, Food Safety and etc. Let our great R & D Team, Manufacturing Team (in Shaoxing) and Sales Team (in Hanzhou) serve you!
Name: Sherry Guan
Mobile:+86 133 3605 7103
Tel:+86 571 8883 7380
Whatsapp:8618506819163
Email:marketing@labfil.com
Add:B-410, No.525 Shixiang Rd, Gongshu District, Hangzhou City, 310011, Zhejiang, China