marketing@labfil.com

Home      Products     Non-Sterile Color Syringe Filter     Nylon Syringe Filter       Labfil Hydrophilic Nylon Syringe Filters

Labfil Hydrophilic Nylon Syringe Filters Non-Sterile 100pcs/pk

  • Labfil Hydrophilic Nylon Syringe Filters Non-Sterile 100pcs/pk

Labfil Hydrophilic Nylon Syringe Filters Non-Sterile 100pcs/pk

  • Category: Nylon Syringe Filter
  • Material: Nylon
  • Pore Szie: 0.22µm 0.45µm
  • Filter Diameter: 13mm 25mm 33mm
  • Color: Yellow
  • Product description:13mm, 25mm, and 33mm Nylon sample syringe filters are for aqueous and organic solution samples.
  • INQUIRY   EMAIL

Description


Product Description

Labfil Nylon filter devices are designed for sterilization and clarification of aqueous and solvent samples in a wide array of analytical and research applications. They are primarily used to filter small aqueous and organic samples with low hold-up volume in order to inject them directly into the HPLC sample loop systems.


Technical Data

Materials Housing PP
Membrane Nylon
Wettability Hydrophilic
Physical Properties Pore Size 0.22 μm, 0.45 μm
Filter Diameter 13mm 25mm 33mm
Filtration Area 0.72cm² 3.4cm² 4.5cm²
Maximum Operating Pressure 6bar 3bar 2bar
pH Range 5.0 – 12.0

Product Information

SKU Material Pore Size Diameter(mm) Sterile Printing Outer Ring Color Packaging
C0000638 Nylon 0.22um 13 NO YES Light Yellow 100pcs/pk.
C0000639 Nylon 0.45um 13 NO YES Yellow 100pcs/pk.
C0000640 Nylon 0.22um 25 NO YES Light Yellow 100pcs/pk.
C0000641 Nylon 0.45um 25 NO YES Yellow 100pcs/pk.
C0000662 Nylon 0.22um 33 NO YES Light Yellow 100pcs/pk.
C0000663 Nylon 0.45um 33 NO YES Yellow 100pcs/pk.


Advantages

* Naturally hydrophilic.

* General sample preparation.

* No pre-rinsing is required.
* Wide chemical compatibility range.

* Strength and dimensional stability.
* Low extractables.


Applications

* Sterilization, clarification of aqueous and organic solvent solutions.
* HPLC sample preparation.
* Chromatography.
* Hydraulic Fluids and Machined Parts.





Select by Sample Volume

Sample Volume Filter Diameter Filtration Area Hold-up Volume Retention Volume
< 10mL 13mm 0.72 cm² < 25μl < 25mL
10mL to 100mL 25mm 3.4 cm² < 100μl < 100mL
100mL to 200mL
33mm
4.5 cm²
 < 125μl
< 125mL

Select by Pore Size

Cleaning Operation Optimal Pore Size
Sterile Filtration 0.20 µm
Thorough Cleaning 0.45 µm
Clear Filtration 1 - 2 µm
Pre-Filtration 5 µm

Select by Diameter

Filter Diameter Volume to be Filtered
4 mm < 1 ml
13 mm 1 - 10 ml
25 mm 10 - 100 ml
30 mm > 100 ml (fast filtration)

Select by Pressure of Syringe Volumes

Syringe Volume Pressure Bar / PSI
1 ml 10 / 150
3 ml 7.0 / 100
5 ml 5.0 / 75
10 ml 3.5 / 50
20 ml 2.0 / 30


How to use a syringe filter?

1. Select the Right Filter:
Membrane Type: Ensure compatibility with your sample (e.g., PTFE for organic solvents, PES for aqueous solutions).
Pore Size: Choose the appropriate pore size (commonly 0.22 µm or 0.45 µm).

2. Prepare the Syringe:
Attach the syringe filter to the syringe securely.
Ensure both are sterile if required.

3. Draw the Sample:
Fill the syringe with the sample, avoiding air bubbles.

4. Filter the Sample:
Hold the syringe with the filter attached.
Press the plunger gently to pass the sample through the filter into a clean container.

5. Post-Filtering:
Ensure the entire sample has been filtered.
Dispose of the used filter according to your lab’s guidelines.

Tips:
Apply steady pressure to avoid damaging the filter.
Pre-filter or centrifuge samples if clogging occurs.


Related Resource

1. What Is a Syringe Filter Used For? A Comprehensive Overview

2. Understanding PTFE Syringe Filters: Applications and Advantages in Laboratory Practice

3. Differences Between Aqueous and Organic Membrane Filters

4. Chemical & Material Compatibility Database

More product knowledge and the latest information are being continuously updated. Please follow our official blog to get the latest industry trends and product information at any time!




WHY CHOOSE US?

* Providing a wide range of Lab consumables.
* Variety OEM/ODM services and short delivery time.
* Rich experience with multinational companies.
* Dimensional accuracy for modern robotic autosamplers.
* Help to collect, identify, organize and protect your samples.
* Class 100,000 grade cleaning room, strict QC and R & D department center.
* With environmentally friendly packaging material.
* Cooperating with famous universities for R&D.
* Superior logistics system to offer door to door services.
* Efficient service and competitive price.

ALWSCI's mission is to provide quality guaranteed products and attentive service for Environmental Protection, Academic Research,Pharmaceutical Manufacture, Food Safety and etc. Let our great R & D Team, Manufacturing Team (in Shaoxing) and Sales Team (in Hanzhou) serve you!


INQUIRY

CONTACT US

Name: Sherry Guan

Mobile:+86 13336057103

Tel:+86 571 88991947

Whatsapp:8618506819163

Email:marketing@labfil.com

Add:B-410, No.525 Shixiang Rd, Gongshu District, Hangzhou City, 310011, Zhejiang, China

Facebook

Linkedin

Youtube

whatsapp

Email

Phone